Sulzer ABS CA 462 Temperature and Leakage Relay
The Sulzer ABS CA 462 is designed to detect leakage and temperature in pumps and mixers. The amplifier is housed in a standard enclosure for DIN-rail mounting and is available in two versions: 110–230 VAC or 24 VDC supply.
To minimise the risk of false alarms, a leakage fault must be present for about 10 seconds before it is signalled. The unit has separate alarm outputs for temperature and leakage, plus a main contactor relay output that is energised depending on the alarms, with a manual reset option. Plug-in connectors make installation simple, and a Xylem MiniCas adaptor is included in the kit.
Main features
- Leakage monitoring with approx. 10 s alarm delay against false alarms
- Wide resistance range for leakage detection, 0–100 kΩ
- Temperature monitoring with PTC or Klixon sensors
- Separate alarm relays for temperature and leakage
- Pump blocking (main contactor) relay with manual reset option
- Plug-in connectors; DIN-rail mounting (35 mm)
- Xylem MiniCas adaptor included
Applications
- Protection of submersible wastewater pumps
- Protection of submersible mixers
- Pumping station control panels
Technical data
| Leakage detection threshold | < 100 kΩ (±10%) |
| Temperature input threshold | > 3.3 kΩ (PTC / Klixon) (±10%) |
| Leakage alarm delay | approx. 10 s |
| Power supply | 110–230 VAC (16907006) or 18–36 VDC SELV / Class 2 (16907007) |
| Max. load alarm relays | 250 VAC, 3 A |
| Max. load pump blocking relay | 250 VAC, 6 A |
| Power consumption | < 5 W |
| Ambient operating temperature | -20 to +50 °C |
| Degree of protection | IP20, NEMA Type 1 |
| Mounting | DIN rail 35 mm |
| Dimensions (H × W × D) | 108 × 70 × 58 mm |
| Compliance | CE, CSA, C/US, UL |
Materials
| Housing | PPO and PC, flame rating V0 |
CA 462 technical data sheet (PDF, Sulzer)